Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note

You must be connected to the TAMU network for this installation. This can be through either TAMU WIFI or VPN. The installation will not complete properly if the device is not on the TAMU network.

  1. Navigate to the link below and login to Microsoft 365 with your TAMU credentials:
    Engineering Software Distribution

  2. Select your current operating system from the options available.

    Image Removed

  3. Select the Base folder.

    Image Removed

  4. Three ISO files are contained within this folder, download the entire folder as shown below.

    Image Removed

  5. Navigate to the download location of the folder, right click the zipped folder, and
    extract the file by clicking Extract All.

    Image Removed

    1. This will create a new unzipped folder of the same name containing the Base folder and the three ISO files as shown below.

      Image Removed

  6. Right-click each of the ISO files and select Mount.

    Image Removed

    1. This will mount a temporary disk to the next available drive letter.

    2. Ensure that this is done for each of the ISO files.

    3. If done correctly, you will have one temporary drive for each disk as follows:

      Image Removed

    4. If the ISO files do not have Mount as an option then you may need to download 7zip.
      Get 7zip

  7. Open the first mounted disk Use USB from Zachry 383

    1. Do not use ANSYS Website

  8. Plug USB into the user’s device and navigate to D:\ANSYS2024R2

  9. Create a “Temp” directory file on the user’s C drive.

    ANSYS 2.jpgImage AddedANSYS 4.jpgImage Added

  10. Copy the “Base” Folder to the new “Temp” folder.

    ANSYS 5.jpgImage AddedANSYS 6.jpgImage Added

  11. Open the Base folder in Temp and open the Setup application.

    Image Removed

    In the installation launcher, select Install ANSYS 7.jpgImage Added

  12. Select “Install Ansys Products.

    Image RemovedANSYS 8.jpgImage Added

  13. Agree to the license agreement and select Next>.

    Image Removed

    Leave the default options ANSYS 9.jpgImage Added

  14. Ensure “Associate file extensions with Ansys products” is selected and select Next>.

    Image Removed

  15. Insert hprc-license.tamu.edu in the Hostname section and select Next>.

    1. Allow access to all firewall requests if prompted.

      Image Removed

  16. Leave Pre-selected Installation Options as default and select Next>.

    Image Removed

    1. Leave the default installation path as C:\Program Files\ANSYS Inc

      ANSYS 10.jpgImage Added

  17. Leave default selected products and click Next>.

    ANSYS 11.jpgImage Added

  18. Leave Interface Configuration values as default and select Next>.

    Image RemovedANSYS 12.jpgImage Added

  19. CAD installs are automatically detected. Select Next>.

    Image RemovedANSYS 13.jpgImage Added

  20. Review install settings and select Next>.

    Image Removed

  21. Wait for the Software to install and fill in the Drive Letters as shown below:

    1. At roughly 42% installation, the installer will generate a prompt requesting the next drive.

    2. Enter the drive letter for Disk 2 and select Ok.

      Image Removed

    3. At roughly 64% it will generate another prompt requesting the next drive.

    4. Enter the drive letter for Disk 3 and select Ok.

      Image Removed

  22. Once the installation reaches 100%, select Next>.

    Image Removed

  23. Exit the installer and launch Ansys to verify the software is running properly.ANSYS step 12.pngImage Added

  24. Once the installation reaches 100%, select Next>

    ANSYS step13.pngImage Added
    1. Takes 20-30 minutes

  25. Licensing Settings 2024 R2 window will open

    ANSYS step 14.pngImage Added

  26. Check the Enabled toggle.

    ANSYS Step 15.pngImage Added

  27. Input the following

    1. Port: 1055

    2. Server 1: Insert hprc-license.tamu.edu

    3. leave Server 2 and Server 3 blank

      ANSYS step 16.pngImage Added

  28. Select Test to check the server's status, and a check (tick) will appear. Select Save.

    ANSYS step 17.pngImage Added
    1. If the test fails, ensure the port and server information is correct

  29. Exit and launch ANSYS

    1. Startup file can be found at C:\Program Files\ANSYS Inc\v242\Framework\bin\Win64\runwb2.exe.

      Screenshot 2024-10-01 091026.pngImage Added

  30. Create shortcut on desktop for easier access to the program.

    Screenshot 2024-10-01 091435.pngImage Added