Note |
---|
You must be connected to the TAMU network for this installation. This can be through either TAMU WIFI or VPN. The installation will not complete properly if the device is not on the TAMU network. |
Use USB from Zachry 383
Do not use ANSYS Website
Plug USB into the user’s device and navigate to D:\ANSYS2024R2
Create a “Temp” directory file on the user’s C drive.
Copy the “Base” Folder to the new “Temp” folder.
Open the Base folder in Temp Navigate to the link below and login to Microsoft 365 with your TAMU credentials:
Engineering Software DistributionSelect your current operating system from the options available.
Select the Base folder.
Three ISO files are contained within this folder, download the entire folder as shown below.
Navigate to the download location of the folder, right click the zipped folder, and
extract the file by clicking Extract All.This will create a new unzipped folder of the same name containing the Base folder and the three ISO files as shown below.
Right-click each of the ISO files and select Mount.
This will mount a temporary disk to the next available drive letter.
Ensure that this is done for each of the ISO files.
If done correctly, you will have one temporary drive for each disk as follows:
If the ISO files do not have Mount as an option then you may need to download 7zip.
Get 7zip
Open the first mounted disk and open the Setup application.
Select “InstallIn the installation launcher, select Install Ansys Products.”
Agree to the license agreement and select Next>.
Ensure “Associate file extensions with Ansys products” is selectedLeave the default options and select Next>
Leave the default installation path as C:\Program Files\ANSYS Inc
Leave default selected products and click Next>.
.
Insert
hprc-license.tamu.edu
in the Hostname section and select Next>.Allow access to all firewall requests if prompted.
Leave Pre-selected Installation Options as default and select Next>.
Leave Interface Configuration values as default and select Next>.
CAD installs are automatically detected. Select Next>.
Review install settings and select Next>.
Once the installation reaches 100%, select Next>
Takes 20-30 minutes
Licensing Settings 2024 R2 window will open
Check the Enabled toggle.
Input the following
Port: 1055
Server 1: Insert
hprc-license.tamu.edu
leave Server 2 and Server 3 blank
Select Test to check the server's status, and a check will appear. Select Save.
If the test fails, ensure the port and server information is correct
Exit and launch ANSYS
Startup file can be found at C:\Program Files\ANSYS Inc\v242\Framework\bin\Win64\runwb2.exe.
Create shortcut on desktop for easier access to the program.
Wait for the Software to install and fill in the Drive Letters as shown below:
At roughly 42% installation, the installer will generate a prompt requesting the next drive.
Enter the drive letter for Disk 2 and select Ok.
At roughly 64% it will generate another prompt requesting the next drive.
Enter the drive letter for Disk 3 and select Ok.
Once the installation reaches 100%, select Next>.